The SineWave Series Is The Best . |
This Is One We Use At GetOffTheGrid.com For Over 4 Years And It Has Worked Perfect. |
|
Premium Power, Premium Efficiency , Premium Inverter |
The SW4024 SineWave and Have Never Had A Glitch. |
|
Problem: Some inverters simply cannot supply power clean enough for equipment like clocks, timers, laser printers, photocopiers, bread makers and pellet stoves. And modified sine wave inverters sometimes cause "noise" on radios or tv sets.
Solution: The Trace SW-series, the world's best and most advanced inverter.
Stacking offers power to spare. Stack the SW in series for 120/240 VAC output and increased total capacity. With a surge rating 2.5 times greater than their continuous power rating, there is almost nothing that will not start and run on one (or two) of these inverters. (Export models are not stackable, including 230 VAC 50 Hz, 105 VAC 50 Hz 105 VAC 60 Hz.)
SW Series II Specifications |
|
|
SW2512 |
SW4024 |
SW3024E |
SW4048 |
SW3048E |
SW5548 |
SW4548E | ||||||||
Nominal DC InputVoltage |
12 VDC |
24 VDC |
24 VDC |
48 VDC |
48 VDC |
48 VDC |
48 VDC | ||||||||
AC Output Voltage (RMS) |
120 VAC |
120 VAC |
230 VAC |
120 VAC |
230 VAC |
120 VAC |
230 VAC | ||||||||
Nominal Frequency |
60 Hz |
60 Hz |
50 Hz |
60 Hz |
50 Hz |
60 Hz |
50 Hz | ||||||||
Continuous Power @ 25°C |
2500 VA |
4000 VA |
3300 VA |
4000 VA |
3300 VA |
5500 VA |
4500 VA | ||||||||
Continuous AC Output (@ 25 °C) |
21 amps |
33 amps |
14 amps |
33 amps |
14 amps |
46 amps |
20 amps | ||||||||
Maximum AC Output (RMS) |
60 amps |
78 amps |
34 amps |
78 amps |
34 amps |
78 amps |
34 amps | ||||||||
Efficiency (peak) |
90% |
94% |
94% |
95% |
95% |
96% |
96% | ||||||||
Automatic AC Transfer Relay |
60 amps |
60 amps |
30 amps |
60 amps |
30 amps |
60 amps |
30 amps | ||||||||
Maximum Charging Rate |
150 amps |
120 amps |
100 amps |
60 amps |
50 amps |
75 amps |
60 amps | ||||||||
DC Input Requirements | |||||||||||||||
Search Mode |
0.08A (1W) |
0.04A (1W) |
0.04A (1W) |
0.025A (1W) |
0.025A (1W) |
0.04A (1W) |
0.04A (1W) | ||||||||
On Mode (no load - idle) |
1.0A (12W) |
0.66A (16W) |
0.66A (16W) |
0.33A (16W) |
0.33A (16W) |
0.40A (20W) |
0.40A (20W) | ||||||||
At Full Rated Power |
275 amps |
200 amps |
166 amps |
100 amps |
83 amps |
137 amps |
106 amps | ||||||||
Short Circuit Output |
700 amps |
360 amps |
320 amps |
180 amps |
160 amps |
180 amps |
138 amps | ||||||||
Nominal DC Input Voltage Range |
11.8 to 16.5 |
22 to 33 |
22 to 33 |
44 to 66 |
44 to 66 |
44 to 66 |
44 to 66 | ||||||||
AC Output Characteristics | |||||||||||||||
AC Output Waveform |
Sine wave, 34 to 52 steps per cycle | ||||||||||||||
Voltage Regulation |
+/- 2% | ||||||||||||||
Total Harmonic Distortion |
3 to 5% (stand alone operation) | ||||||||||||||
Power Factor Allowed |
-1 to 1 | ||||||||||||||
Frequency Regulation |
+/- 0.04% (crystal regulated) | ||||||||||||||
Load Sensing Range |
16 to 240 Watts | ||||||||||||||
Options | |||||||||||||||
Remote Control Panel (50 ft. max.) |
SWRC |
SWRC |
SWRC |
SWRC |
SWRC |
SWRC |
SWRC | ||||||||
Stacking Interface for double power |
SWI* |
SWI* |
No |
SWI* |
No |
SWI* |
No | ||||||||
(*requires two inverters) |
(120/240) |
(120/240) |
|
(120/240) |
|
(120/240) |
| ||||||||
Conduit Box |
SWCB |
SWCB |
SWCB |
SWCB |
SWCB |
SWCB |
SWCB | ||||||||
DC Disconnect Breaker |
DC 250 |
DC 250 |
DC 250 |
DC 175 |
DC 175 |
DC 250 |
DC 175 | ||||||||
DC Battery / Inverter Cables |
BC5-4/0 |
BC5-4/0 |
BC5-4/0 |
BC5-2/0 |
BC5-2/0 |
BC5-4/0 |
BC5-2/0 | ||||||||
Enclosure Type |
Indoor, ventilated, steel chassis with powdercoat finish | ||||||||||||||
Specified Temp Range |
32°F to 104°F (0°C to +40°C) (output will meet specified regulation tolerances) | ||||||||||||||
Allowed Temp Range |
-40°F to 140°F (-40°C to +60°C) | ||||||||||||||
Dimensions - Inverter Only |
15" (38 cm) high, 22.5" (57 cm) wide, 9" (23 cm) deep (wall mounted) | ||||||||||||||
Dimensions - Shipping |
20.5"(52 cm),27"(69 cm),15.5"(40 cm) | ||||||||||||||
Mounting |
Wall or Shelf Mount | ||||||||||||||
Weight - Inverter Only |
90lbs (42kg) |
105lbs (48kg) |
105lbs (48kg) |
105lbs (48kg) |
105lbs (48kg) |
136lbs (63kg) |
136lbs (63kg) | ||||||||
Weight - Shipping |
96lbs (44kg) |
111lbs (50kg) |
111lbs (50kg) |
111lbs (50kg) |
111lbs (50kg) |
143lbs (65kg) |
143lbs (65kg) | ||||||||
Specifications are Provided by Trace Enginnering |
Trace Product Information | |||
SW Series | DR Series | UX Series | U Series |
TS Series | M-Series | DC Disconnect | AC PV Module |
Legend Series | Charge Controllers | Power Panels | Remote & Accessories |
Power Module Systems | Mariner Series |
Created bysolarman@getoffthegrid.com
with homesite 4.01